text.skipToContent text.skipToNavigation

COLLIMATOR BULB

2271727
2259298-99
New
X-Ray
GE HealthCare
GE HealthCare
GE HealthCare
N/A
Outright
Add to Wish List
Sign In & Add To Cart
Sign In & Add To Cart
Please select date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


Features

  • Symmetric rectangular collimation
  • Light to indicate exposure area
  • Laser Bucky light guarantees a sharp line light for all SIDs
  • Light illuminance SID=1m

Product Overview

The Collimator Bulb used in the Proteus Lamb Sub-Assembly. The Proteus XR/a Automatic Collimator uses a special collimator light bulb. When the collimator lamp burns out, it must be replaced with a replacement bulb in the Proteus XR/a renewal parts section. The collimator used a halogen type of light bulb, it is also known as a tungsten halogen, quartz-halogen or quartz iodine lamp. It is an incandescent lamp consisting of a tungsten filament sealed into a compact transparent envelope that is filled with a mixture of an inert gas and a small amount of a halogen such as iodine or bromine. The Proteus XR/a collimator lamp is designed to operate at 24VAC for 150 hours continuous, other type replacement bulbs will burn out much quicker, as they are only designed for 50 hours continuous use at 24VAC. The bulb change is feasible without the realignment of the superposition of light field to X-ray field and is possible without qualified service personnel intervention. This selection process allows the bulb to be replaced by the end user with no alignment required for X-ray to light field.

  • Additional Features

    • Lamp brightness higher than 185 LUX
    • Blade edge contrast higher than 4.5
    • The radiation field - light field tolerance better than 1.2% of SID, at SID=1m
    • RoHS compliant

    Compatible Products

    Definium 8000

    Definium 8000

    Definium 6000

    Definium 6000

    Discovery XR656G2

    Discovery XR656G2

    Optima XR646

    Optima XR646

    Revolution XRd

    Revolution XRd

    Equivalent Part :

    Below is more information on the equivalent parts. Parts without a hyperlink are listed for reference only and are not available for purchase online.

    Equivalent partPart Details
    2259298-99 This 24V 150W Halogen Bulb comes with a 2 Pin, G6.35 base an

    Return And Exchange

    GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.

    Please note, cuffs, BP items, sterile and hazmat items cannot be returned. If a replacement order is requested, the restocking fee may be waived at GE HealthCare’s sole discretion.